1. Introduction

Nowadays, water scarcity is still a big challenge facing humanity in many places around the world. To solve this problem, municipal wastewater has been considered to be an alternative water source for various applications after proper treatment. Among all kinds of treatment processes, membrane bioreactor (MBR) has been increasingly used in municipal wastewater reuse and reclamation applications due to its high effluent quality. When reclamation of the treated water is concerned, much attention has been paid to the presence of some micropollutants, notably the pharmaceuticals, in domestic wastewater due to their potential adverse effects on human health (DAUGHTON and TERNES, 1999; VERLICCHI et al., 2012). Therefore, many studies have been carried out to investigate the removal of pharmaceutical micropollutants in MBR (SIPMA et al., 2010). Also, some studies reported that the presence of pharmaceutical micropollutants in MBR could induce the release of soluble microbial products (SMPs) in MBR (LAY et al., 2012), which may significantly affect the MBR fouling. However, in the literature, very few study investigated the effects of pharmaceutical micropollutants on MBR fouling, which still remains the major limitation for MBR development.

The main objective of this study was to examine the effects of pharmaceutical micropollutants, which are frequently found in municipal wastewater, on the MBR fouling. Carbamazepine (CBZ), an anti-epileptic drug, was selected as a representative compound of pharmaceutical micropollutants in this study because it is one of the most frequently detected pharmaceutical micropollutants in municipal wastewater and it is almost not biodegraded in MBR. A lab-scale submerged MBR, using a flat sheet microfiltration membrane (Kubota, Japan), was used in this study. CBZ was continuously introduced in MBR via the feed (CBZ was added into the feed to 90 µg/L). Fouling in the MBR was characterized by the transmembrane pressure (TMP). HPLC-SEC using a fluorescence detector was used to characterize protein-like SMPs in MBR. Concentrations of proteins and polysaccharides were analyzed in supernatant and permeate of MBR. Fouling propensity of activated sludge was characterized using some standardized filterability tests performed with a stirred dead-end filtration cell.

2. Material and methods

2.1 MBR set-up

A lab-scale submerged MBR set-up consisting of an anoxic reactor (5.4 L) and an aerobic reactor (12.6 L) was used in this study. A flat sheet microfiltration membrane (Kubota, Japan) was submerged inside the aerobic reactor. It has an effective filtration area of 0.1 m2, with an average pore size of 0.2 µm. This MBR was operated at the high sludge retention time (SRT) of 30 days, with a sludge concentration in the aerobic reactor between 6-8 g/L. The instantaneous permeate flux was fixed at 15 L/h/m2 with filtration/relaxation cycles of 8 min/4 min, leading to a net permeate flux of 10 L/h/m2. Municipal astewater was taken from a wastewater treatment plant close to Toulouse, France, after primary physical treatment.

2.2 Analytical methods

Supernatants were prepared by centrifugation of the sludge samples at 4 000 g during ten minutes at room temperature. High performance liquid chromatography—size exclusion chromatography (HPLC—SEC) analysis was performed by an Akta Purifer (GE Healthcare, USA), equipped with a column Protein Kw804 (Shodex, Japan), a silica-based column with an exclusion limit of 1 000 kDa, and a fluorescence detector (Varian, USA). Excitation/emission wavelengths were respectively set at 280/350 nm to detect protein-like substances. Protein concentration in the supernatants, expressed as mg equivalent of bovine serum albumin per liter, was measured by the acid bicinchoninic method (SMITH et al., 1985). Polysaccharide concentration, expressed as mg equivalent of glucose per liter, was measured by the Anthrone method (DREYWOOD, 1946). The values of protein and polysaccharide concentration are the average of three repetitions.

2.3 Filterability tests

Filterability tests were carried out in an Amicon cell (Millipore), with an effective membrane filtration surface of about 13.4 cm2, at constant transmembrane pressures (TMP) of 0.5 bar, using 150 kDa polyethersulfone (PES) membranes. A new membrane sample was used for each filtration test. During the filtration, the sludge was stirred at 200 rpm.

3. Results and discussion

3.1 Effects of CBZ on MBR sludge

3.1.1 Effects of CBZ on biomass

Sludge microbial activity was characterized by the exogenous respiration rate in respirometric batch experiments. A slight but not significant inhibition of microbial activity was observed (results not shown here). Also, no significant difference on floc size distribution was found after addition of CBZ in MBR (results not shown here).

3.1.2 Effects of CBZ on supernatant

Figure 1 shows that after addition of CBZ in MBR, a significant increase in protein SMPs in MBR supernatant was observed whereas no significant difference on the retention of protein SMPs was found, which indicated that the increased protein SMPs were mainly relatively small molecules that could pass through MBR membrane. Figure 1 also showed that several days after the addition of CBZ the protein SMPs in supernatant started to decrease until to the original level after about two weeks after the addition of CBZ, which also indicated the acclimation of biomass to CBZ stress. Moreover, no significant change in polysaccharide SMPs was found.

Figure 1

Effects of CBZ on the concentration of soluble microbial products

L'impact de CBZ sur concentration de produits microbien solubles

Effects of CBZ on the concentration of soluble microbial products

-> Voir la liste des figures

Figure 2 shows that the protein-like SMPs in MBR supernatant display bimodal distribution. After addition of CBZ in MBR a decrease of 100-1 000 kDa protein-like SMPs was observed, which may be caused by the inhibition of sludge microbial activity; whereas a more significant increase of 10-100 kDa protein-like SMPs was found, which may be caused by the microbial response when facing pharmaceutical stress.

Figure 2

HPLC-SEC analysis of MBR supernatants

Analyse de HPLC-SEC sur surnageant de BAM

HPLC-SEC analysis of MBR supernatants

-> Voir la liste des figures

3.2 Effects of CBZ on membrane fouling

3.2.1 Effects of CBZ on fouling propensity of MBR sludge

Figure 3 shows that the fouling propensity, expressed as the fouling resistance (Rf), of activated sludge increased after addition of CBZ in MBR, which confirmed the important role of 10-100 kDa protein-like SMPs in the biocake structure during the sludge filtration, since no significant change in biomass quality was observed.

Figure 3

Filterability tests of MBR sludges on 150 kDa polyethersulfone (PES) membranes

Tests de filtration des boues de BAM sur membranes de 150 kDa polyethersulfone (PES)

Filterability tests of MBR sludges on 150 kDa polyethersulfone (PES) membranes

-> Voir la liste des figures

3.2.2 Effects of CBZ on MBR fouling

Figure 4 presents the time-variation of TMP during operation of the MBR. Four different periods and comportments can be distinguished: (1) Before the addition of CBZ in the MBR quite steady fouling conditions were reached, where TMP increases very slowly; (2) One day after addition of CBZ in MBR, a significant increase of TMP, a “TMP jump”, was observed; (3) Between one day and eight days after addition of CBZ, TMP increased gradually while at a higher rate as compared to that before addition of CBZ; (4) Staring from eight days after addition of CBZ, a continuous TMP jump started to occur, where TMP increased at a much significantly higher rate. The sudden significant increase of 10-100 kDa protein-like SMP one day after addition of CBZ in MBR (see figure 2) may cause a sudden loss of voids in the biocake that was formed on the MBR membrane surface and change the structure of the biocake, which could explain the sudden increase of TMP one day after addition of CBZ in MBR. The accumulation of 10-100 kDa protein-like SMPs in the biocake may result in the gradual while more rapid increase of TMP and finally caused the TMP jump. The compressing effect of biocake may also contribute to the continuous TMP jump (results not shown here).

Figure 4

Effect of CBZ on the transmembrane pressure in the MBR

L'impact de CBZ sur la pression transmembranaire du BAM

Effect of CBZ on the transmembrane pressure in the MBR

-> Voir la liste des figures

4. Conclusion

In conclusion, the continuous CBZ pollution in MBR led to a significant increase of MBR fouling, which could be related to the increase of 10-100 kDa protein-like SMPs in MBR supernatant. The 10-100 kDa protein-like SMPs could modify the structure of the biocake on membrane surface and result in internal fouling in the biocake.